Dell R300 Network Card User Manual


 
About Your System 27
E161C PS # Input
Lost
Power source for specified
power supply is unavailable,
or out of acceptable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 133.
E1624 PS Redundancy The power supply subsystem
is no longer redundant. If
the last supply fails, the
system will go down.
See "Troubleshooting
Power Supplies" on
page 133.
E1710 I/O Channel
Chk
The system BIOS has
reported an I/O channel
check.
See "Getting Help" on
page 165.
E1711 PCI PERR B##
D## F##
The system BIOS has
reported a PCI parity error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 147.
PCI PERR Slot
#
The system BIOS has
reported a PCI parity error
on a component that resides
in the specified PCIe slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 147.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions