Dell R300 Network Card User Manual


 
About Your System 41
Time-of-day not set
- please run SETUP
program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Entering the
System Setup Program" on
page 45. If the problem
persists, replace the system
battery. See "Troubleshooting
the System Battery" on
page 132.
Timer chip counter
2 failed
Faulty system board. See "Getting Help" on
page 165.
TPM configuration
operation honored
System will now restart. Information only.
TPM failure A Trusted Platform
Module (TPM) function
has failed.
See "Getting Help" on
page 165.
TPM operation is
pending. Press I to
Ignore or M to
Modify to allow
this change and
reset the system.
WARNING: Modifying
could prevent
security.
Configuration change has
been requested.
Press I to continue system
boot. Press M to modify the
TPM setting and restart.
Unexpected
interrupt in
protected mode
DIMMs are improperly
seated or the
keyboard/mouse controller
chip has failed.
Reseat the DIMMs. See
"Troubleshooting System
Memory" on page 135. If the
problem persists, see
"Getting Help" on page 165.
Unsupported DIMM
detected in the
RAID DIMM slot!
DIMM installed in RAID
DIMM slot is not
supported.
See "Troubleshooting System
Memory" on page 135. If the
problem persists, see
"Getting Help" on page 165.
Table 1-7. System Messages (continued)
Message Causes Corrective Actions