Dell R300 Network Card User Manual


 
Troubleshooting Your System 141
9
Reconnect the system to the electrical outlet, and turn on the system and
attached peripherals.
If the problem is not resolved,
see
"Getting Help" on page 165
.
Troubleshooting a SCSI Tape Drive
Problem
Defective tape drive
Defective tape cartridge
Missing or corrupted tape-backup software or tape drive device driver
Defective SCSI controller
Action
1
Remove the tape cartridge you were using when the problem occurred, and
replace it with a tape cartridge that you know works.
2
Ensure that the SCSI device drivers for the tape drive are installed and are
configured correctly. See "Optical Drive" on page 79.
3
Reinstall the tape-backup software as instructed in the tape-backup
software documentation.
4
Ensure that the tape drive’s interface/DC power cable is connected to the
tape drive and SCSI controller card.
5
Verify that the tape drive is configured for a unique SCSI ID number and
that the tape drive is terminated or not terminated, based on the interface
cable used to connect the drive.
See the documentation for the tape drive for instructions on selecting the
SCSI ID number and enabling or disabling termination.
6
Run the appropriate online diagnostics tests. See "Using Dell PowerEdge
Diagnostics" on page 151.
7
Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.