62
3.5.3.8 Clear Robot Failure (1000)
(1) Function
This command clears a robot failure that has been caused.
(2) Format
Command area (4 bits, input)
1000
Data area 1 (8 bits, input)
Nothing will be input.
Data area 2 (16 bits, input)
Nothing will be input.
Status area (16 bits, output)
Nothing will be output.
(3) Description
If a robot failure occurs, this command clears it. When there is no failure,
no processing will take place
When an error is displayed, the same processing as when the OK or
Cancel key of the operating panel or the teach pendant is operated will be
performed.