13-26 SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
The RAID-capable IOUA contains the RAID controller. When the RAID-capable IOUA is
replaced, the disks comprising the RAID boot volume must be reactivated to be able to boot.
This is done from OpenBoot PROM via the OpenBoot PROM command
activate-volume.
1. Confirm that the RAID volume is no longer listed.
2. Select the device and confirm that the RAID volume is reported but inactive.
{0} ok probe-scsi-all
/pci@0,600000/pci@0/pci@4/scsi@0
MPT Version 1.05, Firmware Version 1.32.06.00
arget 4
Unit 0 Removable Read Only device TEAC DV-W28S-V J.0B
SATA device PhyNum 4
{0} ok select /pci@0,600000/pci@0/pci@4/scsi@0
{0} ok show-volumes
Volume 0 Target 82 Type IM (Integrated Mirroring)
Optimal Enabled Inactive
2 Members 585805824 Blocks, 299 GB
Disk 1
Primary Online
Target 0 FUJITSU MBD2300RC 3702
Disk 0
Secondary Online
Target 1 FUJITSU MBD2300RC 3702