Fujitsu M8000 Server User Manual


 
25-4 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
8. Confirm that the addition components are normal by using the showhardconf or
showstatus command of XSCF.
If "*" is not displayed for the addition FRU, it is operating normally.
Note – The showhardconf command cannot check the PCI card, Hard Disk Drive, and
tape drive unit. To check the Hard Disk Drive and tape drive unit, use the
probe-scsi-all command from the ok prompt. To check the PCI card, use the
show-devs command from the ok prompt.
9. When CMUs or IOUs are added, perform the SB settings and domain settings for
each CMU and IOU.
Ask a system administrator or a domain administrator for assistance.
10. Set the mode switch on the operator panel to Locked.
25.2 Deletion
The procedure of deletion is intended for the following FRUs:
CPU/memory board unit (CMU)
I/O unit (IOU)
PCI card (PCI)
The FRUs allow for active deletion and cold deletion, as well as regular replacement. In
addition, the FRUs have the following features.
CMU and IOU allow the active deletion using the DR function.
PCI card (including link card) allows the active deletion using the PHP function.
Caution – For deletion, a filler panel (TABLE 25-1) must be installed in the empty slot.
Without filler panels, the system might overheat.
XSCF> showhardconf
TABLE 25-1 Filler Panels
Slot location Filler panel name
CMU CMU filler panel
IOU IOU filler panel
PCI PCI filler panel