Fujitsu M8000 Server User Manual


 
14-14 SPARC Enterprise M8000/M9000 Servers Service Manual October 2012
10. Mount the replacement CD-RW/DVD-RW drive unit by following the removal
instructions in Step 8 in reverse order.
Caution – Do not forcibly push the CD-RW/DVD-RW drive unit when inserting it, even if
it is not moving smoothly. You may fail to insert the CD-RW/DVD-RW drive unit due to the
presence of any obstruction in a slot or any problem with a connector pin; and if you forcibly
insert it, serious damage may result.
11. Switch on all main line switches for the AC section (ACS) in the power supply
system.
12. Confirm that the XSCF STANDBY LED (green) on the operator panel remains lit.
If it is blinking, wait until it remains lit.
13. Use one of the following methods to start (power on) all domains at once.
Press and hold down (for less than four seconds) the POWER switch on the operator
panel.
From a console that is connected to XSCF, execute the poweron -a command of XSCF.
For details of the power-on operation, see Section 4.4.2, “Powering the Server On” on
page 4-22, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide.
14. Start the domain as necessary.
15. Restore the original mode switch setting on the operator panel.
Note – When the maintenance work is completed, be sure to confirm the mode switch
setting and return the switch to Locked.
16. Close the door on the server, and lock it.