Fujitsu M8000 Server User Manual


 
22-1
CHAPTER
22
Media Backplane Replacement
This chapter explains the replacement procedure for media backplanes (MEDBPs). It covers
the following:
Section 22.1, “Overview of the MEDBP” on page 22-1
Section 22.2, “Cold Replacement” on page 22-5
As a replacement method for MEDBPs, only the cold replacement method can be used. For
the definition of the replacement method, see Section 4.1, “Types of Replacement
Procedures” on page 4-2.
22.1 Overview of the MEDBP
This section provides an overview of MEDBPs and describes their mounting locations.
A MEDBP provides the connectors for mounting a tape drive unit (TAPEU) and
CD-RW/DVD-RW drive unit (DVDU) in a cabinet. These connectors serve as sockets on the
cabinet side for connecting a tape drive unit and CD-RW/DVD-RW drive unit to the cabinet.
A MEDBP is further connected to a switch backplane, through which it connects the tape
drive unit or CD-RW/DVD-RW drive unit to the IOU. Active maintenance cannot be
performed on a MEDBP.
FIGURE 22-1, FIGURE 22-2, and FIGURE 22-3 show the mounting locations of the MEDBP of
the M8000 server, the M9000 server (base cabinet), and the M9000 server (with the
expansion cabinet), respectively.