HP (Hewlett-Packard) 300 All in One Printer User Manual


 
5-53
Problem Resolution
Parameter # Description Units
9 Ring envelope maximum ON time. Maximum time an entire ring signal can be
present to be counted as 1 ring. The entire ring signal may consist of several ring
bursts separated by periods of silence.
Country
Default
United States 8000
Australia 8000
France 8000
Germany 8000
Netherlands 8000
United Kingdom 8000
India 8000
Korea 8000
China 8000
1 ms
(50 ms to
10000 ms)
10 Ring envelope minimum OFF time. Minimum time between ring envelopes, where
each ring envelope may consist of a single or multiple rings. Once this time has
expired the ring count is incremented.
Country
Default
United States 1000
Australia 1000
France 1000
Germany 1000
Netherlands 2000
United Kingdom 1000
India 1000
Korea 1000
China 1000
1 ms
(200 ms to
20000 ms)
11 Ring envelope maximum OFF time. Maximum time between ring envelopes after
which the ring count is reset to zero. When this period of silence has expired all
ringing is considered complete.
Country
Default
United States 8000
Australia 8000
France 7000
Germany 8000
Netherlands 8000
United Kingdom 8000
India 8000
Korea 8000
China 8000
1 ms
(200 ms to
20000 ms)