HP (Hewlett-Packard) 300 All in One Printer User Manual


 
5-54
Problem Resolution
Parameter # Description Units
12 Ring burst minimum ON time. Minimum time a single ring signal must be active
before it is counted. If this time is not exceeded the ring burst is ignored.
Country Default
United States 100
Australia 100
France 100
Germany 250
Netherlands 100
United Kingdom 100
India 100
Korea 100
China 100
1 ms
(50 ms to
1000 ms)
14 Ring burst minimum OFF time. Minimum time that must occur between two ring
bursts if they are to be counted as two individual bursts.
Country Default
United States 100
Australia 100
France 100
Germany 250
Netherlands 100
United Kingdom 100
India 100
Korea 100
China 100
1 ms
(50 ms to
1000 ms)
15 Minimum number of rings. This is the minimum ring count the user can enter. This
is used for data entry validation only.
Country Default
United States 1
Australia 1
France 2
Germany 2
Netherlands 2
United Kingdom 2
India 1
Korea 1
China 1
1 ring (1 ring
to 15 rings)
16 Maximum number of rings. This is the maximum ring count that the user can enter.
This is used for data entry validation only.
Country
Default
United States 6
Australia 6
France 5
Germany 6
Netherlands 7
United Kingdom 6
India 6
Korea 6
China 6
1 ring (1 ring
to 15 rings)