HP (Hewlett-Packard) 300 All in One Printer User Manual


 
5-60
Problem Resolution
Parameter # Description Units
35 Modem loop current test enable. Controls if a modem loop current test is
performed after HP OfficeJet Series 300 has connected to the external line and
before dialing is started.. If TRUE, HP OfficeJet Series 300 will test for the
presence of loop current after going OFF hook prior to dialing. If loop current is
not detected, the fax session is aborted.
Country Default
United States 0
Australia 1
France 1
Germany 1
Netherlands 1
United Kingdom 1
India 0
Korea 0
China 0
0 = FALSE
1 = TRUE
36 Modem loop current detection time minimum. Minimum time that continuous
modem loop current must be present when the machine fist connects and a loop
current test is performed. Also, this is the minimum time that loop current must be
absent once dialing has completed, when performing the loop current failure test.
Country
Default
United States 0
Australia 200
France 250
Germany 200
Netherlands 200
United Kingdom 200
India 0
Korea 0
China 0
1 ms
(0 ms to
15000 ms)
37 Modem loop current detection delay. The delay that occurs before starting the loop
current failure test. Allows time for the network to settle after dialing and prevents
”open switch interrupts” from falsely being interpreted as problems with the
connection.
Country
Default
United States 0
Australia 10000
France 10000
Germany 10000
Netherlands 10000
United Kingdom 10000
India 0
Korea 0
China 0
1 ms
(0 ms to
15000 ms)