Hypercom 1101 Network Router User Manual


 
IN-tact 1101 Software Configuration Guide 95
Trap Definitions
For manual time synchronization, the SynchronizeSNTP variable can be used. It is a read-write
variable with noAction and synchronize as its values.
System Error Codes
StaticAlternateNTPServer Read-write variable. IP address or name of static alternate
NTP server.
SntpSynchronizationInterval Read-write variable. Integer with valid values from 1 through
24.
Error Code Error Description SNMP Trap
Event Logger Events
00-00 Bad log message -- invalid subsystem 0x%x Yes
00-01 Bad log message -- invalid ordinal 0x%x for subsystem 0x%x Yes
Kernel Events
01-00 Assert failed in function %s line %d Yes
01-01 Configuration saved -- restarting Yes
01-02 System error -- restarting Yes
01-03 Reverting to default configuration Yes
01-04 Reverting to factory default Yes
01-06 Start: LAN MAC %s IP %s Yes
SDLC Events
02-05 Unable to remove header prior to sending rx data to client Yes
02-06 Initial offset too large for the buffer Yes
02-07 Initial length too large for the buffer Yes
02-08 Unable to format buffer from pool %d Yes
02-09 Error attempting to add a header to a buffer Yes
02-10 Retrieved an application frame which is not a buffer Msg %d Yes
02-11 Mailbox %d is full -- message discarded Yes
02-12 Unable to acquire buffer from pool %d Yes
02-13 Internal state error for address %02x eDropState=0x%2x Yes
02-14 Unable to cancel POSIX resource %d Yes
02-15 Retrieved an invalid event message %x Yes
02-16 Error reading from HDLC -- %s Yes
02-17 Invalid length %d bytes read from HDLC Yes
SCC Event
03-00 Receive buffers exhausted. Frame discarded. Yes
Variable Description