Lexmark C910 5055-01x Printer User Manual


 
3-8 Service Manual
5055-01x
Print Tests
Input Source Print Tests
The Diagnostic Input Source Print Tests may be used to verify that
the printer can print on media from the installed input sources, which
are available within the Print Tests menu. Chose from following:
Single (prints the Print Test page once).
Continuous (prints the Print Test page until Return or Stop is
pressed).
The content of the Print Test page varies depending on the media
installed in the selected input source. If a source is selected that
contains paper, then a page similar to the Quick Test page prints. If a
source is selected containing envelopes, the Envelope Print Test
pattern prints. This pattern contains text of each character in the
selected symbol set.
If Continuous is selected, all sources printing with paper sizes will
print the same page continuously until the test is stopped. If the
source contains envelopes, then the envelope print test pattern
prints on the first envelope and subsequent envelopes are blank.
Note: The Print Test page can be printed on any paper or envelope
size. More than one sheet of some media sizes may be required.
The Print Test page will always print in simplex.
While the page prints, the following message displays.
The Power indicator also blinks while the page prints. If Single is
selected, no buttons are active while the Print Test page prints. If
Continuous is selected, Return or Stop can be pressed to cancel
the test, producing the following message:
<Source>
Printing...
Cancelling...
Service.bk Page 8 Thursday, October 4, 2001 12:20 PM