Lexmark J110 Printer User Manual


 
Repair Information 4-49
4085-001
Peristaltic Pump Removal
1. Remove the rear cover. Refer to Rear Cover Removal on
page 4-3.
2. Remove the exit tray. Refer to Exit Tray Removal on page 4-5.
3. Remove the operator panel cover. Refer to Operator Panel
Cover/Operator Panel Removal on page 4-5.
4. Remove right cover. Refer to Right Cover/Power Switch
Removal on page 4-9.
5. Remove the power supply and tank.
Note: When reinstalling the pump, be sure the gear alignment is
correct.
6. Remove the two screws from the peristaltic pump and
disconnect the pump from the gear.
Tray 2 Covers Removal
1. Remove ten screws {A} from Tray 2 covers.
2. Remove the covers.