5.5 Administrator Mode Operations
5
CF2002/CF3102 5-45
Utility Mode Operations Chapter 5
19
If the lines are shifted as shown at the
right, touch [Y], and then touch
to specify the desired negative
adjustment for “Y” (between -1 dot and
-6 dots).
20
If the lines are shifted as shown at the
right, touch to specify the
desired positive adjustment for “Y”
(between +1 dot and +6 dots).
21
Press the [Start] key. The adjusted test pattern is printed on 11 × 17-size paper.
22
Check the print result. If the distance between the reference line of the black
lines and the cyan lines is adjusted to 0, skip to step 23.
❍
If more adjustment is necessary, return to step 14 and repeat the adjustment
procedure.
23
Touch [Enter]. The Expert User’s Mode screen appears again.
24
Touch [Color Shift Correction(M)]. Repeat the procedure for adjusting the cyan
shift (steps 13 to 23) to adjust the magenta shift.
25
Touch [Color Shift Correction(Y)] and repeat the same procedure for the yellow
shift.
26
Touch [Enter].
The Expert User’s Mode screen appears again.
27
Touch [Fin. Time] again in the next three screens that appear.