Mitel 3300 Network Hardware User Manual


 
3300 ICP Hardware User Guide
124 Release 3.3
To complete the installation of the Mitel Networks 3300 ICP:
1. Connect power to the 3300 Controller. The controller will come up, in 15 to 20 minutes,
with factory-installed software.
2. To check the connections between the 3300 Controller and the PC:
PING the 3300 Controller IP address
FTP to the 3300 Controller IP address
Go to the 3300 Controller URL address (http://192.168.1.2).
3. Launch browser to login to the System Administration Tool (http://192.168.1.2 -- username
is system, password is password).
4. Optional. Install the Mitel Networks 3300 Configuration Tool on your PC. Use the Config-
uration Tool to reset the default database, import the .csv file, and make programming
changes. Refer to the 3300 Configuration Tool online help for detailed instructions.
5. Enable the options in the License and Option Selection form.
6. If you have a database backup, restore the customer data to the system, and then skip to
step 12 (Perform a backup). If there is no database to restore, proceed to step 7.
7. Reboot the system.
8. Once the system has come back up, enter the DBMS Save command and wait until
completed.
9. Verify that the DBMS Save was correctly performed by entering the DBMS Stat command.
10. Program the system using the System Administration Tool.
11. Configure the DHCP Server with IP addresses provided by the customer. Refer to the
Note and default settings table following this procedure.
12. Perform a Backup.
13. Reboot the system.
14. Set the 3300 Controller (RTC) IP address through a communication program.
15. Install the other units as described in the System Installation Overview.
16. As the final step, connect the 3300 Controller to the LAN.
Note: A Reboot is only required here if programming is completed manually.
Note: You may use the internal or an external DHCP Server. The controller is shipped
with the DHCP server Enabled. Use DHCP reservations against the MAC address for
the E2T.
Internal DHCP Server default settings - shipped enabled
TFTP Server 066 192.168.1.2
TFTP BootFile 067 /sysro/E2T8260
IP Phone TFTP Server 128 192.168.1.2
MN330 (RTC) IP Address 129 192.168.1.2
Mitel IP Phone DHCP Server 130 MITEL IP PHONE
Range Start
End
192.168.1.20
192.168.1.24