Installing
Release 3.3 125
Set the 3300 Controller IP Address
To set the 3300 Controller IP address:
1. Establish a serial connection from the 3300 Configuration Tool PC (or any PC equipped
with a communications program) to the Maintenance Port on the 3300 Controller.
2. Launch the communication program.
3. Set the RS-232 communication parameters:
• Baud rate - 9600
• Data bits - 8
•Parity - None
• Stop bits - 1
• Flow control - None
4. Connect AC power to the 3300 Controller.
5. Press the Reset button on the 3300 Controller with a small, pointed object.
6. Wait for the "Press any key to stop auto-boot" message and then press a key.
7. At VxWorks Boot, type c and then press Enter.
Press Enter after you enter the required text. For all other fields, (displayed in italics, for
information only) accept the default value or leave blank.
• boot device: ata=0,0 (Boot device is Disk)
• unit number: 0 (default, leave at 0, not used)
• processor number: 0 (default, leave at 0, not used)
• host name: (optional)
• file name: /sysro/Rtc8260 (boot location and file name)
• inet on ethernet (e): 134.199.63.11:ffffff00 (example RTC IP and subnet mask)
• inet on backplane (b):
• host inet (h):
• gateway inet (g): 134.199.63.251 (example Router (Gateway)address)
• user (u): ftp (must be ftp for Release 3.1)
• ftp password (ftp) (blank = @):
• flags (f): 0x0 (a fixed IP address (0x40 is used on E2T for DHCP)
• target name (tn):
• startup script (s):
• other (o): motfcc (other device, E2T using Network to boot from)
Note: Type the IP address and subnet mask. The subnet mask must be in hexadecimal
format for the end user’s site (for example. ffffff represents 255.255.255.00).
Note: Enter the IP address of the end user's gateway for the 3300 Controller.