Specifications
Release 3.3 47
250 User System with 30 Voice Mail Ports
This system uses:
One 300 MHz RTC
One 300 MHz E2T
One 64 Channel Echo Canceller
One Dual FIM
One DSP Module (21061/21161) for telecom support
One DSP Module (21161) for 30 Voice Mail Ports
This provides:
Four DSP devices (21061/21161) for telecom functions for up to 250 users
30 Voice Mail Ports
64 Channels of Echo Cancellation
Two External FIM connections
Four ASU connections (CIM ports)
The four external FIM connections are for providing connectivity for up to four Peripheral Units
or up to eight NSUs. Note that there are two T1/E1 links per NSU.