3300 ICP Hardware User Guide
194 Release 3.3
SX-2000 LIGHT to 3300 ICP
To upgrade SX-2000 LIGHT hardware for 3300 control:
• 384 port Peripheral - main control replacement
• DSU - main control replacement
• Peripheral cards - DNIC Line, ONS CLASS, ONS Line, LS/GS Trk, E&M Tie Trk, OPS
Line, DID/Loop Tie
• DSU cards - T1 (DS1) Formatter, CEPT Interface, ISDN PRI, E1/T1 Dig Trk Formatter, E1
R2, 6CCT BRI, 15CCT BRI
• If existing capacity is greater than that of the 3300 ICP, the conversion will fail. See the
capacity table for the 3300 ICP.
The SX-2000 LIGHT Digital Services Unit (DSU) cabinet provides digital trunk capability, and
the SX-2000 LIGHT peripheral cabinet provides connectivity for analog trunks, analog
telephones, and Mitel DNI devices. Both cabinet types can be connected to the 3300 Controller
by using multi-mode fiber connections.
The DSU cabinet supports BRI, PRI, T1/D4, MSDN/DPNSS, and DASS II trunks.
The peripheral cabinet supports the following analog trunks:
• Analog CO trunks
• E&M trunks
• Direct Inward Dial and Tie Trunks.
The peripheral cabinet also supports the following DNI telephones and devices:
• SUPERSET 401
• SUPERSET 401+
• SUPERSET 410
• SUPERSET 420
• SUPERSET 430
• SUPERSET 4001
• SUPERSET 4015
• SUPERSET 4025
• SUPERSET 4125
• SUPERSET 4150
• SUPERCONSOLE 1000.
For additional information, refer to SX-2000 technical documentation.