3300 ICP Hardware User Guide
176 Release 3.3
Before you begin:
• Ensure that the upgrade kit is complete.
• Check each module to ensure that no damage has occurred in transit.
• You will need a Philips screwdriver.
• Have a 3300 ICP system back-up.
Caution: To prevent ESD damage while handling modules on any unit, always attach the
wrist strap from the cabinet being serviced, and immediately place any item removed
from a cabinet into an anti-static bag.
You can also migrate:
• SX-2000 LIGHT to 3300 ICP
• SX-2000 MICRO LIGHT to 3300 ICP
• 3200 ICP to 3300 ICP
• 3800 WAG to 3300 ICP.
100 User System - Add Voice Mail Ports
100 user system upgrade to add support for 30 voice mail ports.
This system uses the following existing modules:
• One embedded 300 MHz RTC/E2T processor
• One embedded 64 Channel Echo Canceller
• One Dual FIM
• One 21161 based DSP Module for telecom support
Add the following module:
• One DSP Module (21161) for 30 Voice Mail Ports
This provides:
• 4 DSP devices for telecom functions for up to 100 users
• 30 Voice Mail Ports
• 64 Channels of Echo Cancellation
Note: There may be system limitations when migrating. Check the appropriate system
configuration guidelines.