Mitel 3300 Network Hardware User Manual


 
3300 ICP Hardware User Guide
74 Release 3.3
- A ground connector.
Peripheral Unit Dimensions
Peripheral Unit Environment
Physical Dimensions
Height 19 inches (48.0 cm)
Width 18 inches (45.8 cm)
Depth 16.5 inches (42.0 cm)
Weight 95 lbs (43.2 kg)
Storage Environment
Condition Specification
Temperature -40º to 150ºF (-40º to 66ºC)
Humidity 5-95% Relative Humidity, non-condensing
Vibration
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical Stress One 20.3 cm (8 inch) drop, each edge and corner adjacent to the rest
face – unpackaged
Horizontal Transportation
Impact Stress
One shock pulse applied on each face perpendicular to the direction
of motion of the transporting vehicle; the shock pulse is a half-sine
acceleration 30 g peak, 20 ms duration
Operational Environment
Condition Specification
Temperature 32º to122ºF (0º to 50ºC)
Humidity 5-95% Relative Humidity, non-condensing
Maximum Heat Dissipation
- fully loaded (see Note)
724 BTUs per hour
Air Flow 150 cubic feet per minute at maximum output of the fans
Radiated Emissions The system meets Class A limits as outlined in FCC Rules, Part 15,
Subpart J
Conducted Emissions The system meets Class A limits as outlined in FCC Rules, Part 15,
Subpart J, and complies with conducted emissions standards as
outlined in BS800
Acoustic Emissions Maximum 50 dBA continuous, 75 dB intermittent (<10% duty cycle)
Static Discharge Withstands 50 discharges of each polarity through a 10 k resistor
connected to a 60 pF capacitor charged to 20 kV, and 20 discharges
of each polarity through 500 ohm resistor connected to a 100 pF
capacitor charged to 10 kV
Lightning Surge 2.5 kV peak, with a maximum rise time of 2 µs and minimum decay
time of 10 µs applied to power lead terminals, and 800 V peak with a
maximum rise time of 10 ms and minimum decay time of 560 ms
applied to outside plant interface terminals
Induction (Normal) 50 Vrms at 60 Hz, open circuit, longitudinal mode (Tip and Ring to
ground)