3300 ICP Hardware User Guide
66 Release 3.3
3300 ASU and Universal ASU Power
3300 ASU and Universal ASU Pin Allocations
Power Supply Input Specifications
Note: Connector is a Standard Male IEC320 AC input.
Voltage Universal input design, operating input voltages from 90VAC to 264VAC.
It regulates a +5, -48V, -30V, -5V, 70VAC ringing signal, and the –115VAC
Message Waiting Signal.
Current < 1.0A RMS at 90VAC and full rated load.
Frequency AC input frequencies from 47Hz to 63Hz.
Holdover With an input voltage of 120VAC or 240VAC under a full rated load, the
power supply outputs remain in regulation for a minimum of 16ms after loss
of AC mains input voltage.
Brown-Out Recovery Recovers from an AC input brown-out or sag condition automatically.
CIM Connector Pin Allocations
Pin Signal Pin Signal
1 RX+ 5 Not Used
2 RX- 6 TX-
3 TX+ 7 Not Used
4 Not Used 8 Not Used
Note: The 3300 Universal ASU connects to the 3300 Controller over a Category 5 Universal Twisted
Pair (UTP) cross-over cable through a CIM interface. The Category 5 cable is of the same type used
for Ethernet connections and within the cable twisted pairs are arranged as: 1,2: 3,6; 4,5; 7,8. Each
tied pair is connected to a 75 ohm resistor. The 3300 Universal ASU can be located up to 30 meters
(98.4 feet) away from the 3300 Controller. The interface employs a single standard 8-pin modular jack
consisting of 2 balanced signal pairs and is located on the front of the unit.
25 pair Connector Pin Allocations
Pin Signal Pin Signal
Note: Connection of the Tip and Ring (A and B) leads of the ONS lines and LS trunk circuits are
through a 25 pair female D-type connector.
1 ONS Tip 1 26 ONS Ring 1
2 ONS Tip 2 27 ONS Ring 2
3 ONS Tip 3 28 ONS Ring 3
4 ONS Tip 4 29 ONS Ring 4
5 ONS Tip 5 30 ONS Ring 5
6 ONS Tip 6 31 ONS Ring 6
7 ONS Tip 7 32 ONS Ring 7
8 ONS Tip 8 33 ONS Ring 8
9 ONS Tip 9 34 ONS Ring 9
10 ONS Tip 10 35 ONS Ring 10
11 ONS Tip 11 36 ONS Ring 11
12 ONS Tip 12 37 ONS Ring 12