Mitsubishi Electronics Q64TCRTBWN Network Card User Manual


 
325
CHAPTER 7 PROGRAMMING
7
7.2 When Using the Module in a Standard System Configuration
7.2.2 Standard control (peak current suppression function, simultaneous temperature rise function)
*1 Configure this setting only when the simultaneous temperature rise function is used.
*2 Configure this setting only when the peak current suppression function is used.
Simultaneous
temperature rise
group setting*1
Set a group to perform the
simultaneous temperature rise
function for each channel.
1: Group 1 1: Group 1 2: Group 2 2: Group 2
Peak current
suppression control
group setting*2
Set the target channels for the
peak current suppression
function and the gap of the
control output cycle between
channels.
1: Group 1 2: Group 2 3: Group 3 4: Group 4
Simultaneous
temperature rise AT
mode selection*1
Set the mode of the auto
tuning.
1: AT for
Simultaneous
Temperature Rise
1: AT for
Simultaneous
Temperature Rise
1: AT for
Simultaneous
Temperature Rise
1: AT for
Simultaneous
Temperature Rise
Alert 1 mode setting Set the alert mode.
1: Upper Limit
Input Alert
1: Upper Limit
Input Alert
1: Upper Limit
Input Alert
1: Upper Limit
Input Alert
Alert set value 1
Set the temperature where
CH Alert 1 (b8 of Un\G5 to
Un\G8) turns on.
250°C 300°C 350°C 400°C
Item Description
Set value
CH1 CH2 CH3 CH4