Mitsubishi Electronics Q64TCRTBWN Network Card User Manual


 
384
Auto refresh setting
Set the buffer memory for each channel in the Q64TCN where auto refresh is performed.
• Write data error code • CH alert definition
•CH temperature process value (PV) CH alert set value 1
•CH manipulated value (MV) • CH alert set value 2
•CH set value (SV) setting CH alert set value 3
•CH proportional band (P) setting • CH alert set value 4
•CH integral time (I) setting • CT heater disconnection alert setting
•CH derivative time (D) setting • CT heater current process value
•CH loop disconnection detection judgment time CH manipulated value (0-4000/0-12000/0-16000)
•CH transistor output flag • CH temperature rise judgment flag
Values stored in the buffer memory in the Q64TCN where the auto refresh setting is configured are
automatically read when the CPU module executes END instruction.
Monitor/test
Monitor/test the buffer memory and I/O signals of the Q64TCN.
Also the auto tuning function can be executed.
• Write data error code • CH Alert 2
•CH decimal point position • CH Alert 3
•CH temperature process value (PV) CH Alert 4
•CH manipulated value (MV) • CH Heater disconnection alert
•CH set value (SV) setting CH Loop disconnection alert
•CH transistor output flag • CH Output off-time current error alert
•CH ON delay output • CH alert 1 mode setting
• Cold junction temperature process value • CH alert set value 1
• X00: Module ready flag • CH alert 2 mode setting
• X01: Operation mode status • CH alert set value 2
• X02: Write error flag • CH alert 3 mode setting
• X03: Hardware error flag • CH alert set value 3
• X04: CH1 auto tuning status • CH alert 4 mod
e setting
• X05: CH2 auto tuning status • CH alert set value 4
• X06: CH3 auto tuning status • Alert dead band setting (× 0.1%)
• X07: CH4 auto tuning status • Alert delay count
•X08: E
2
PROM write completion flag
•CH loop disconnection detection judgment time
(Unit: s)
• X09: Default value write completion flag • CH loop disconnection detection dead band
•X0A: E
2
PROM write failure flag
•CH heater disconnection alert setting (%)
• X0B: Setting change completion flag
• Heater disconnection/output off-time current error
detection delay count
• X0C: CH1 alert flag
• Heater disconnection compensation function
selection
• X0D: CH2 alert flag • CT monitor method switching
• X0E: CH3 alert flag • CT heater current process value
• X0F: CH4 alert flag • CT channel assignment setting
• Y01: Operation mode command • CT CT selection
• Y02: Error reset command • CT reference heater current value
Function Description