3107
The CC-Link parameter setting is
incorrect.
• Correct and write the network
parameters.
• If the error occurs after correction, it
suggests a hardware fault. (Please
consult your local Mitsubishi
representative.)
QS
3150
The network No. set in Network
parameter for CC-Link IE Field Network
is overlapped with the one set for
another network module.
Check the parameter setting.
QS
*3
3400
The start I/O number of the target
module in Remote password is set to
other than 0
H to 3E0H.
Change the start I/O number of the
target module to the number within 0
H to
3E0
H.
QS
3401
Ethernet module of function version B
or later is not mounted on the slot
specified for the start I/O number of
Remote password.
Mount the Ethernet module of function
version B or later on the slot specified
for the start I/O number of Remote
password.