Mitsubishi Electronics QSPCU Personal Computer User Manual


 
12
TROUBLESHOOTING
12.3 Error Code List
12.3.5 Error code list (3000 to 3999)
12 - 44
9
EMC AND LOW
VOLTAGE
DIRECTIVES
10
LOADING AND
INSTALLATION
11
MAINTENANCE AND
INSPECTION
12
TROUBLESHOOTING APPENDICES INDEX
3107
The CC-Link parameter setting is
incorrect.
• Correct and write the network
parameters.
• If the error occurs after correction, it
suggests a hardware fault. (Please
consult your local Mitsubishi
representative.)
QS
3150
The network No. set in Network
parameter for CC-Link IE Field Network
is overlapped with the one set for
another network module.
Check the parameter setting.
QS
*3
3400
The start I/O number of the target
module in Remote password is set to
other than 0
H to 3E0H.
Change the start I/O number of the
target module to the number within 0
H to
3E0
H.
QS
3401
Ethernet module of function version B
or later is not mounted on the slot
specified for the start I/O number of
Remote password.
Mount the Ethernet module of function
version B or later on the slot specified
for the start I/O number of Remote
password.
QS
Error
Code
(SD0)
Error Contents and Cause Corrective Action
Corresponding
CPU