8310
The installed product is different from
the specified one by network parameter.
Check that [Model name], [Module
technical version] or [Production
information] of the CC-Link Safety
remote station set in the network
parameter matches the product
information of the relevant CC-Link
Safety remote station.(Refer to the
manual of the CC-Link Safety remote
module for the confirmation.)
QS
8320
The response data cannot be received
during the initial processing of CC-Link
Safety remote station.
• Check that the following operations
are not executed.
(1)Switching the operation mode
(2)Writing the program memory to
ROM
(3)Registration/change of the CPU
access password
(4)Initialization of PLC memory
(If executed, this error may occur due
to the increase of the interval between
data communications of CC-Link
Safety.)
• When instantaneous power failure
occurs to the supply power, change to
the asynchronous mode or slow down
the speed.
• Execute the link test to check the
soundness of transmission path.
• Check the setting of transmission
speed.
• Check if the setting value of the
Safety refresh monitoring time is
appropriate.
• Check if the setting value of the
Safety data monitoring timer is
appropriate.
QS
8321
The response data cannot be received
during the normal communication with
CC-Link Safety remote station.
QS
8322
The response data cannot be received
during processing error information
from CC-Link Safety remote station.
QS
Error