The underlining indicates the factory setting.
400 STILL TIMER 0000
0001
0002
0003
0004
0005
0006
0007
0008
0.5s
5s
10s
20s
30s
40s
50s
1min
2min
This selects the time taken for the unit to be set to the tape
protection mode when it has been left standing in the STOP or
search STILL (JOG, VAR or SHTL) mode.
(Units: s = second, min = minute)
403 STOP PROTECT
0000
0001
STEP
HALF
This selects the tape protection mode operation when the unit has
been left standing in the STOP mode.
0: Step FWD
1: Half loading
<Note>
When step FWD has been set, the unit is automatically transferred
to the half loading mode when it has been left standing for a total
of 30 minutes in the STOP mode.
401 SRC PROTECT
0000
0001
STEP
HALF
This selects the tape protection mode operation when the unit has
been left standing in the STILL mode.
0: Step (or step FWD in STILL mode).
1: Half loading
<Note>
When step FWD has been set, the unit is automatically transferred
to the half loading mode when it has been left standing for a total
of 30 minutes in the STILL mode.
402 DRUM STDBY
0000
0001
OFF
ON
This selects the drum operation in the standby OFF mode.
0: The drum is stopped.
1: The drum is rotated.
[[
[[
[[
[[
Item Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
V
T
R
1
V
T
R
2
40
Setup menus
TAPE PROTECT menu