Panasonic AJ-B95 Laptop User Manual


 
87
Display tube Description
E
59
Superimposed
display
DRUM ROTA TOO
SLOW
VTR operation
Auto OFF
This appears when the cylinder motors rotation speed is
abnormally low.
E
59
DRUM ROTA TOO
FAST
Auto OFF
This appears when the cylinder motors rotation speed is
abnormally high.
E
64 S REEL TOO FAST Auto OFF
This appears when the supply reel motors rotation speed is
abnormally high.
E
67 T REEL TOO FAST Auto OFF
This appears when the take-up reel motors rotation speed is
abnormally high.
E
69
T REEL TORQUE
ERR
Auto OFF
This appears when an abnormal torque applied to the take-up
reel motor has been detected.
E
70
S REEL TORQUE
ERR
Auto OFF
This appears when an abnormal torque applied to the supply
reel motor has been detected.
E
71
CAP TENSION
ERROR
Auto OFF
This appears when an abnormal supply tape tension has been
detected in the capstan mode.
E
72
REEL TENSION
ERROR
Auto OFF
This appears when an abnormal supply tape tension has been
detected in the reel mode.
E
73
REEL DIR
UNMATCH
Auto OFF
This appears when the take-up reel motor has rotated in the
reverse direction.
E
81 SOL NG Power OFF
This appears when a problem has been detected in the
solenoid drive circuit. After this error message appears, the
power is forcibly turned off.
E
82 C SOL NG Power OFF
This appears when a problem has been detected in the
cleaning solenoid drive circuit. After this error message
appears, the power is forcibly turned off.
E
BA BATTERY Power OFF
This appears when the input DC voltage drops below the
undercut voltage (approx. 10.6V).
After this error message appears, the power is forcibly turned
off.
E
61
CAP ROTA TOO
SLOW
Auto OFF
This appears when the capstan motors rotation speed is
abnormally low.
Error Messages