Paradyne 6800 Network Cables User Manual


 
Connecting the Components
4-256800-A2-GN22-30 January 1997
Materials Required
To connect COMSPHERE 3400/4400 Series Model 2 APL modems, COMSPHERE 3600 Series
DSUs, COMSPHERE 3800 Series DDD modems, COMSPHERE 3900 Series APL modems,
DATAPHONE II APL and DDD modems, and DATAPHONE II DSUs, you will need the
following materials:
002-0025-0031 adapter (for a modem chain beginning with a Model 2 modem)
035-0145-5031 cable (for a modem chain beginning with a Model 2 modem or for a
4000 Series Intelligent Communications Carrier (ICC) or 3000 Series Carrier)
035-0154-0031 cable (for a modem chain beginning with a DATAPHONE II modem)
835-3564-2511 cable (for a modem chain beginning with a DATAPHONE II modem)
5506-06 hubbing device for 3400 Model 2 modems
3600-F3-300 hubbing device for 3600/3800/3900 Series devices
Connection Procedures
For a modem chain beginning with a COMSPHERE 3400 Series, 3600 Series, or 3800 Series
devices, perform the following steps:
1. Connect the 002-0025-0031 adapter to one of the connectors on the octopus cable attached
to the DCP/MUXi card in the host processor.
2. Connect the 035-0145-5031 cable to the 002-0025-0031.
3. Connect the other end of the 035-0145-5031 cable to the CCIN/DCOUT jack of the
hubbing device attached to the COMSPHERE device.
For a modem chain beginning with a DATAPHONE II modem, perform the following steps:
1. Connect the 835-3564-2511 cable to one of the connectors on the octopus cable attached to
the DCP/MUXi card in the host processor.
2. Connect the other end of the 835-3564-2511 cable to the 035-0154-0031 cable.
3. Connect the other end of the 035-0154-0031 cable to the CC-IN jack of the DATAPHONE
II modem.
For either a 4000 Series ICC housing 4400 Series Model 2 modems or a 3000 Series Carrier
housing 3600 Series DSUs, 3800 Series DDD modems, or 3900 Series APL modems, perform the
following steps:
1. Connect the 002-0025-0031 adapter to one of the connectors on the octopus cable attached
to the DCP/MUXi card in the host processor.
2. Connect the 035-0145-5031 cable to the 002-0025-0031 adapter.
3. Connect the other end of the 035-0145-5031 cable to the CCIN jack on the carrier. When
connecting carriers together in a chain, use the 035-0109-0031 cable.