Paradyne 6800 Network Cables User Manual


 
Loading and Restoring Software
5-996800-A2-GN22-30 January 1997
6. When asked to display the system summary,
TYPE: n
PRESS: Enter
7. Reset the host computer. Refer to Chapter 6, System Start-up and Shutdown.
Removing a 6510 Configuration
The following procedure provides information on removing a 6510 configuration from the 6800
Series NMS database.
1. The ANALYSIS Selection menu (Figure 5-11) is displayed on your screen. The letter n
represents the number of ANALYSIS 6510’s already configured.
To remove a 6510 configuration from the 6800 Series NMS database.
TYPE: 2
PRESS: Enter
2. The system displays the following message:
Warning! The following steps will be taken if you continue.
1. The 6510 support software in the 6800 NMS will be stopped.
2. All Historic Alert records and Trouble Tickets for the 6510 and its devices will be
deleted from the NMS database.
3. All Facility Profiles having the 6510 or its devices at both endpoints
(point-to-point circuits) will be deleted.
4. NOTE! Facility Profiles and bridging devices related to multipoint circuits will
NOT be deleted.
Do you wish to continue? (y or n)...
TYPE: y
PRESS: Enter
3. The following message appears:
Please select the 6510
1. “System name”
2. Cancel operation
Enter a number from 1 to 7 depending on the number of 6510’s already configured
TYPE: number of the system to be removed
PRESS: Enter