Paradyne 6800 Network Cables User Manual


 
COMSPHERE 6800 Series Network Management System
4-42 January 1997 6800-A2-GN22-30
2. Depending on the application, connect the other end of the 035-0153-0031 cable to the
002-0040-0031 (male) or 002-0052-0031 (female) connector.
3. Connect the 002-0040-0031 or 002-0052-0031 connector to the terminal port of the
computer system requiring VT100 terminal emulation.
Connecting Remotely
To connect a remote computer system requiring VT100 terminal emulation, you will need the
following materials:
035-0153-0031 cable
002-0039-0031 connector
Two DCE devices with the following characteristics:
Asynchronous
Full-duplex
Flow control ON
Bit rates of 1200, 2400, 4800, 9600, 19,200 bps
835-5783-0011 cable (depending upon the computer system you are connecting to, you may
need an 835-3564-2511 cable, which is male to female, instead of the 835-5783-0011 cable,
which is male to male)
To establish the connection, perform the following steps at the processor end:
1. Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600
card in the host processor or UIP.
2. Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.
3. Connect the 002-0039-0031 connector to the local DCE.
Perform the following steps at the remote end:
1. Connect the male end of the 835-5783-0011 or the 835-3564-2511 cable to the remote
DCE.
2. Connect the male end of the 835-5783-0011 or the female end of the 835-3564-2511 cable
to the terminal port of the computer system requiring VT100 terminal emulation.