Paradyne 6800 Network Cables User Manual


 
COMSPHERE 6800 Series Network Management Systems
C-10 January 1997 6800-A2-GN22-30
Table C-1
NMS Commands
Command Name Function
dsdp
Display Device Profile Use this command to check the System Polling field.
It must be set to mux poll to permit the multiplexer to
be monitored for alerts and events.
eddp
Edit Device Profile Use this command to set the System polling field to
mux poll.
dsams
Edit Alert Monitoring State Use this command to check the Polling state field. It
must be set to polling, polling and asynch report-
ing, or asynch polling for control channel m2 to
detect faults associated with the multiplexer.
edams
Display Processing Filter Use this command to set the Polling state field to
polling, polling and asynch reporting, or asynch
polling on for control channel m2.
dspf
Display Alert Monitoring State Use this command to display the processing filter
value for each alert group of the device type specified.
edpf
Edit Processing Filter Use this command to change the value of the filters
that define an active alert.
dsdf
Display Display Filter Use this command to display the display filter value
for each alert group of the device type specified.
eddf
Edit Display Filter Use this command to change the value of the filters
that define the alerts that will display on the network
map, network monitor, and network summary.
You should also check the Edit User Selection Criteria (edusc) command to see if the alerts you are
interested in are configured for display on your individual monitor.
If you have verified that all connections and software configuration entries are correct, and that the
multiplexer hardware is functioning, you should check the host processor for failure.