Paradyne 6800 Network Cables User Manual


 
COMSPHERE 6800 Series Network Management System
8-8 January 1997 6800-A2-GN22-30
Figure 8-4. Port-to-Port Connections
d. To run the test,
TYPE: SPIOTEST SIOx SIOy
Where: SIOx represents the ID number of the transmitting port and
SIOy represents the ID number of the receiving port.
PRESS: Enter
e. When the test is finished, you will be returned to the MS-DOS operating system. If
the system hangs while running this test, you will have to reboot. Then, check to see
that the driver is properly installed and the cabling is correct.
12. The third diagnostic tests the transmit circuit of a particular serial port. If the previous
test produced a negative result, you can use this test to determine the functionality of the
transmit circuit. To run this test, you must have a terminal connected to a port, as
described in the first test. Once you have this, perform the following steps:
a. To run the test,
TYPE: CTEST SIOx
Where: SIOx is the ID number of the transmitting port.
PRESS: Enter
b. When the test is finished, you will be returned to the MS-DOS operating system.