Paradyne 6800 Network Cables User Manual


 
Connecting the Components
4-316800-A2-GN22-30 January 1997
One Local ACCULINK Multiplexer and One 719 NETWORKER
If only one 74x multiplexer is present at the local site, a 719 NETWORKER can be used to
multiplex the alert and cut-through information over a single supervisory data link (SDL).
The alert and cut-through connections enter the 719 NETWORKER via channel ports. The SDL
exits the 719 NETWORKER through a link and connects to one of the 74x NAPs. The second
NAP is devoted to the command port. Each multiplexer port on the 74x and 719 NETWORKER
must be software configured. Figure 4-18 shows the connections for one local ACCULINK
multiplexer and one 719 NETWORKER.
Host
Processor
NAP
Port 1
ACCULINK MUX
NAP
Port 2
IPC-1600
Card
= 002-0039-0031 Connector
= 002-0021-0031 Connector
Channel
Channel
Link
719 NETWORKER
035-0153-0031
835-3564-0011
Event
Port
External
Systems
Port
Command
Port
493-13910-02
035-0153-0031
035-0153-0031
Figure 4-18. Connections for One Local ACCULINK Multiplexer and One 719 NETWORKER