Paradyne 6800 Network Cables User Manual


 
COMSPHERE 6800 Series Network Management System
8-14 January 1997 6800-A2-GN22-30
8. Select Start Address and
PRESS: Enter
9. Select the Correct Window size/address combination and
PRESS: Enter
Addresses are listed in Table 2-1 (for 5000 host) and Table 2-5 (for 15000 host). (All
window sizes for the EMULEX DCP/MUXi cards are 16KB.) The Select Window Size
menu is displayed.
10. Select 16KB and
PRESS: Enter
11. Exit the configuration menu and return to the Main Menu:
PRESS: Esc
12. Select Run and
PRESS: Enter
NOTE
The EMULEX DCP/MUXi diagnostics automatically test to see if the
local processor can interrupt the host. The EMULEX DCP/MUXi
cards are configured without using interrupts. The diagnostics will
erroneously flag this as an error. This is not an error, so ignore the
error message.
13. The system prompts:
Local processor did not interrupt host --> FAIL
***Pausing on error ---> Type any key to continue:
PRESS: Enter
14. When the diagnostics are completed, the system prompts:
Type any key to proceed.
PRESS: Enter
The Main Menu is displayed. To test a second EMULEX DCP/MUXi card or to repeat
the test, return to Step 5. Otherwise, continue.
15. Select Exit and
PRESS: Enter
16. At the DOS prompt, remove the floppy disk and
PRESS: Ctrl + Alt + Del
to reboot the system or run the next DOS-based diagnostics program.