11-1Installation
CHAPTER 11
INSTALLATION
Introduction
This
chapter explains P9012 printer installation procedures. The following
topics are covered:
n P
ower R
equirements
n
Site R
equirements
n
Shipping R
estraints
n P
aper Stacking Chain Assembly Installation
n
Cable Connections
n P
reliminary T
est
Be sure to read this chapter carefully before installing and operating the printer. Perform the
procedures
in the order presented.
- CAUTION -
To
avoid shipping
damage, reinstall the shipping restraints whenever the printer is
moved or shipped.
- VORSICHT -
Um Versandschäden zu verhindern, die Versand-Einspannungen wieder einĆ
bauen, wenn der Drucker versetzt oder versand wird.
Power Requirements
- CAUTION -
When
the printer is powered-up, it draws 84 amperes, 1/2 cycle average. This is an
important power consideration. It is recommended that printer power be supplied
from
a separate AC circuit protected at 20 amperes for 110 volts, or 10 amperes for
220
volts at 50 or 60 Hz, even though the printer will not rise in excess of 15 amperes
at 110 volts.
- VORSICHT -
Wenn
der Dr
ucker angetrieben wird, benutzt er 84 Ampere mit einem Durchschnitt
von 1/2 Zyklus. Dies ist ein wichtiger Stromhinweis. Es wird empfohlen, dass der
Strom von einem separaten Wechselstromkreis dem Drucker zugeführt wird, der
mit
20 Ampere für 110 V
olt oder 10 Ampere
für 220 V
olt mit 50 oder 60 Hz geschützt
ist, obwohl der Drucker nicht über 15 Ampere mit 110 Volt ansteigen wird.