Configuration3-6
Load Configuration Values
The previously saved default value set or the permanently stored Printronix factory value set
can be loaded for use as needed. The following procedure provides a convenient method of
resetting
the printer configuration to a known value set.
1. Place
the printer off line and raise the printer cover. Enable the ENTER switch by press
Ć
ing
MENU UP and MENU DOWN simultaneously. ENTER SWITCH NOT LOCKED
will temporarily appear in the LCD message display.
2. Select and display the LOAD PARAMETERS main menu by pressing MENU DOWN
and
then NEXT or PREV
.
3. Press
MENU DOWN and then PREV or NEXT to select either the
LO
AD S
A
VED P
AĆ
RAMETERS
or
LO
AD F
ACTOR
Y P
AR
AMETERS menu. If an IGP
, IBM 3287, or IBM
5225 emulation board is installed, select the appropriate standard configuration listed in
this
menu.
4. Press ENTER once the desired selection is displayed in the LCD. The display will show
LOAD
S
AVED COMPLETED or LO
AD F
ACTORY COMPLETED.
5. To permanently save a configuration after all parameters have been changed as desired,
select the SAVE PARAMETERS main menu and press ENTER. This will save the curĆ
rent parameter values as the default values.
6. P
ress CLEAR to return to OFFLINE READ
Y.
7. Disable the ENTER switch by pressing MENU UP and MENU DOWN simultaneously.
Close the printer cover and place the printer on line.