Raritan Computer Paragon switch Switch User Manual


 
18 PARAGON ADMINISTRATORS INSTALLATION AND OPERATION GUIDE
Multi-Tier Installation
Paragon’s channel capacity can easily be expanded with a tiered installation. Up to three tiers are
possible: a base plus a maximum of two levels of tiered KVM switches. When setting up two tiers,
the base unit must be a Paragon switch and the second tier can be any of the Raritan KVM Switches
listed below. In a three-tier configuration, both the base unit and the second tier must be Paragon
Switches; the third tier can be any of the Raritan KVM Switches listed below.
Raritan KVM switches that can be tiered off of a Paragon Switch unit include: other Paragon
Switches, Z-Series Z4200U, MasterConsole MX
4
, MasterConsole MXU2, and MasterConsole II (Model
MCC).
Up to 2,048 computers can be accommodated with a multi-tier installation. Only computers
may be
connected to channel ports of the final tier KVM switches.
Figure 16 Example of a Multi-Tier Configuration
Important: In multi-tier configurations, the order of powering ON is critical to proper function.
Last tier switches must be powered ON before the intermediate level of tier
Intermediate tier switches must be powered ON before the base Paragon switch can be
powered ON.
User Stations (UST1s) can be powered ON and OFF at any time as needed.
There is a five-second ON/OFF down time in the UST1 or Paragon power cycle.