Raritan Computer Paragon switch Switch User Manual


 
62 PARAGON ADMINISTRATORS INSTALLATION AND OPERATION GUIDE
CIM models capable of accepting a UST1 Direct Mode connection include:
UKVMC
UKVMP
UKVMPD
UKVMP2
USKVMC
USKVMP
USKVMPD
USKVMPA
UUSBPD
Setting a UST1 to Direct Mode:
1. Power OFF the UST1.
2. Connect desired CIM directly to the UST1 via Category 5e UTP cable.
3. At the user console connected to the UST1, simultaneously hold down the <Ctrl> and <Alt>
keys.
4. Continue to hold the <Ctrl> and <Alt> keys and power ON UST1.
5. Continue to hold the <Ctrl> and <Alt> keys. There will be two beeps. At the second beep, a
message on the user console monitor will appear: “DIRECT Mode: CIM connected.”
6. Release the <Ctrl> and <Alt> keys.
7. The “DIRECT Mode: CIM connected” message will disappear after 10 seconds.
8. The UST1 is now set in Direct Mode.
Note: If the Category 5e UTP cable is disconnected from either the CIM or the UST1
in the Direct Mode connection for a time period greater than three to four seconds,
Direct Mode will be cancelled. To re-establish Direct Mode on the UST1, follow the
steps above.
Returning a UST1 to Normal Paragon Mode:
1. Power OFF UST1.
2. Disconnect the Category 5e UTP cable from the CIM.
3. Connect the Category 5e UTP cable from the UST1 to a Paragon switch.
4. Connect the Paragon switch to the CIM via Category 5e UTP cable.
5. Power ON UST1.