AX3500 Motor Controller User’s Manual 147
Accessing & Changing Configuration Parameter in Flash
Syntax: %rrrrrr
Reply: None. Controller will reset and display prompt message
Accessing & Changing Configuration Parameter in Flash
It is possible to use RS232 commands to examine and change the controller’s parameters
stored in Flash. These commands will appear cryptic and difficult to use for manual param-
eter setting. It is recommended to use the Graphical configuration utility described in
“Using the Roborun Configuration Utility” on page 181. Note that many parameters will
not take effect until the controller is reset or a special command is sent. The complete list
of parameters accessible using these commands is listed in “Automatic Switching from
RS232 to RC Mode” on page 169. Reading and writing parameters is done using the fol-
lowing commands:
Read parameter
Syntax: ^mm
Reply: DD
Where mm= parameter number
DD= current parameter value
Example:
^00 Read value parameter 0
01 Controller replies, value is 01
Modify parameter
Syntax: ^mm nn
Reply: + if command was executed successfully
- if error
Where mm= parameter number
nn= new parameter value
Examples:
^02 03 Store 03 into parameter 2
Notes:
All parameters and values are expressed with 2 hexadecimal digits
No changes will be made and an error will be reported (“-” character) when attempting to
read or write a parameter that does not exist or when attempting to store a parameter with
an invalid value.
Apply Parameter Changes
Description:
Many parameters will take effect only after the controller is reset. This command can be