General Operation
46 AX3500 Motor Controller Users Manual Version 1.9b. June 1, 2007
The relation between Battery Current and Motor current is given in the formula below:
Motor Current = Battery Current / PWM Ratio
Example: If the controller reports 10A of battery current while at 10% PWM, the current in
the motor is 10 / 0.1 = 100A.
Important Warning
Do not connect a motor that is rated at a higher current than the controller. While
the battery current will never exceed the preset Amps limit, that limit may be
reached at a PWM cycle lower than 100% resulting in a higher and potentially unsafe
level through the motor and the controller.
Regeneration Current Limiting
The AX3500s current sensor is capable of measuring current in the reverse flow (regener-
ation). Using this capability, the controller will automatically relax the braking effect of the
power output stage to keep the regeneration current within safe values. Because of the
controllers high current handling capabilities, this protection mechanism activates only
when abrupt deceleration are applied to high-inertia, ultra-low impedance motors.