RoboteQ AX3500 Computer Accessories User Manual


 
AX3500 Motor Controller Users Manual 59
Connecting devices to Output C
**These connections should only be done in RS232 mode or R/C mode with radio pow-
ered from the controller.
Connecting devices to Output C
Output C is a buffered, Open Drain MOSFET output capable of driving over 2A at up to 24V.
The diagrams on Figure 28 show how to connect a light or a relay to this output:
8 Digital In
and Analog
In
R/C: Ch 3 R/C radio Channel 3 pulses - (Not available
onAX3500)
RS232: Input E / Ana in
4
Analog Input 4 in RevB Hardware
Ana: Input E / Ana in 4 Channel 2 speed or position feedback input in
RevB Hardware
10 Analog in
RC/RS232: Ana in 2 Channel 2 speed or position feedback input
Analog: Command 2 Analog command for channel 2
11 Analog in RC/RS232: Ana in 1 Channel 1 speed or position feedback input
Analog: Command 1 Analog command for channel 1
12 RC: Unused
RS232: Ana in 3 Analog input 3
Ana: Ana in 3 Channel 1 speed or position feedback input in
RevB Hardware
14 Power Out +5V +5V Power Output (100mA max.)
15 Input Input EStop/Inv Emergency Stop or Invert Switch input
TABLE 10. DB15 connector pin assignment
Pin
Number
Input or
Output
Signal depending
on Mode Description