Sun Microsystems V40z Server User Manual


 
4-16 Sun Fire V20z and Sun Fire V40z Servers—User Guide March 2005
FIGURE 4-7 Removing or Installing a Vertical PCI Card That Does Not Have an MRL
Caution – Before you power on a Sun Fire V40z server the first time, you must open
the top cover and remove the packaging insert from the server’s PCI slots to ensure
proper air flow and cooling. You can discard this packaging insert, which serves as
protection during shipping.
Do NOT remove the plastic air-baffle inserts from the PCI slots.
3. Remove the card you are replacing. If the slot is blank, remove its metal slot cover
from the back panel and remove any plastic air-baffle insert from the PCI slot.
Note – On the updated release (chassis PN 380-1206) of the server, a plastic
air-baffle cage has been added and replaces the individual air-baffle inserts. When
adding or removing a PCI card, you do not need to remove the air-baffle cage.
4. Insert the new card into the slot. Push down evenly on both corners of the card to
ensure it is seated correctly.