DEVELOPMENT SYSTEM
12
12 - 7
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
12.4.3 Adjustment using the temperature / humidity sensor
Variation in the output (V
ATS
) of the auto-toner sensor due to humidity is corrected using the tempera-
ture / humidity sensor to maintain the toner density in the developer material at a certain amount.
12.4.4 Adjustment using the drum thermistor
Variation in the output (V
ATS
) of the auto-toner sensor due to temperature is corrected using the drum
thermistor to maintain the toner density in the developer material at a certain amount.
Feedback control by drum thermistor in setting mode (08)
Code Item to be controlled Default
08-840 Toner output control by drum thermistor ON