6. DIAG. TEST OPERATION
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.
2. Max. fine adjustment
±
9.9 mm = Key fine adjustment value (
±
9.5 mm) + PC fine
adjustment value (
±
9.9 mm)
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3. A changed back feed value is stored in memory by pressing the [PAUSE] key.
[FEED] key: Pressing the [FEED] key one
time is a -0.5 mm change, up to
-9.5 mm. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key
one time is a +0.5 mm change,
up to +9.5 mm. (See NOTE 2.)
6.3 PARAMETER SETTING MODE
6.3.3 Back Feed Length Fine Adjustment
<
1 DIAGNOSTIC V1.0A
>
<
2 PARAMETER SET
>
B
A K FEED ADJ.+0.0mm
C
Power off
Press the [FEED] key.
Press the [PAUSE] key three times.
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.4
X axis fine adjustment.
Turn on the power while
hoding down the [FEED]
key and [PAUSE] key.