Toshiba B-570 SERIES Printer User Manual


 
6-4
EM18-33010A
6. DIAG. TEST OPERATION
#
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
NOTES: 1. Item from (2) through (10) are initialized to “0” after RAM clear.
2. If the distance is 5.5 m or less, it is rounded down and no data is added to the memory at power
off.
3. If the count is 31 counts or less, it is rounded down and no data is added to the memory at
power off.
4. If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory
at power off.
5. When a sent command results in an error, the same number as the data capacity of the
command is counted by byte.
Fig. 6-1
(Revision Date: Dec. 10 ‘99)
6.2 SELF TEST MODE
Sample Print
[Print Condition]
Preset count : 1
Print speed : 127 mm/sec.
Sensor : No sensor
Printing method : Thermal transfer
Supply length : 50 mm
Issuing mode : Batch printing
(without rewinder)
1) Maintenance Counter
Item
Total media distance
covered
Media distance
Print distance
Cut count
Head up and down
count
Ribbon motor driving
time
Solenoid driving time
RS-232C hardware
error count
System error count
Momentary power
failure count
Count Condition
Counted when the feed motor drives to feed, print and
issue the media. (Counted also during ribbon save
operation and back feed.) [See NOTE 2].
Counted while printing. (Feeding and issuing media,
and ribbon saving operation are not counted.)
[See NOTE 2.]
Counts every cut. [See NOTE 3.]
Counts every up and down of the print head using the
solenoid for ribbon save operation.
(Up + Down = 1 count) [See NOTE 3.]
Counts when the ribbon motor drives to feed, print
and issue the media. (The driving time is not counted
during ribbon saving operation, but is during back
feed.) [See NOTE 4.]
Counted during ribbon saving operation.
[See NOTE 4.]
Counted when a parity, overrun or framing error
occurs. [See NOTE 5.]
Counted when a zero-dividing error occurs or
undefined command is retrieved.
Counted when a momentary power failure occurs.
Range
0.0 ~ 3200.0 km
0.0 ~ 200.0 km
0.0 ~ 200.0 km
0 ~ 1000000 times
0 ~ 2000000 times
0 ~ 2000 hours
0 ~ 1000 hours
0 ~ 255 times
0 ~ 15 times
0 ~ 15 times
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(25)
(26)
(27)
(28)
(29)
(30)
(31)
(32)
(33)
TL FEED 1882.3km
FEED 20.5km
PRINT 15.0km
CUT 148150
HEAD U/D 170
RIBBON 32h
SOLENOID 0h
232C ERR 1
SYSERR 0
PW FAIL 0
FONT [PC-850] [0]
CODE [ESC LF NUL]
RIBN [TRANS.]
[PC]
FEED -10.0mm
CUT -5.0mm
BACK +3.0mm
TONE(T) +3step
TONE(D) +5step
[KEY]
FEED +5.0mm
CUT -1.5mm
BACK +0.5mm
TONE(T) +0step
TONE(D) +1step
X ADJ. +35.0mm
RIBN ADJ. [PC] + 0 +0 [KEY] + 0 +0
STATUS [OFF]
THRESHOLD R 1.0V
THRESHOLD T 1.4V
KANJI [TYPE1]
EURO CODE B0H
STACKER [OFF]
DTR/RTS [DTR]
INPUT PRIME [ON]
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)