Toshiba B-570 SERIES Printer User Manual


 
6-34
EM18-33010A
6. DIAG. TEST OPERATION
6.3.14 Threshold Manual Fine Adjustment for the Feed Gap Sensor
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.
2. A changed threshold fine adjustment value is stored in memory by pressing the
[PAUSE] key.
3. The above operations do not require any more threshold setting.
[FEED] key:
Pressing the [FEED] key onetime is a -0.1V
change, up to 0.0V
[RESTART] key:
Pressing the [RESTART] key onetime is a
+0.1V change, up to 4.0V.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [PAUSE] key.
Press the [PAUSE] key sixteen times.
<
1 DIAGNOSTIC V1.OA
>
<
2 PARAMETER SET
>
TH ESHOLD T 1.4VR
Press the [FEED] key or
[RESTART] key to fine
adjust the feed gap sensor
manual threshold.
Press the [FEED] key
and [RESTART] key at
the
same time.
Press the [PAUSE] key.
Continued on Section
6.3.15 Kanji Code
Selection.
(Revision Date: Dec. 10 ‘99)
6.3 PARAMETER SETTING MODE