Toshiba M1 Laptop User Manual


 
3 Tests and Diagnostics 3.4 System Test
3-10 TECRA M1 Maintenance Manual (960-436)
3.4 System Test
To execute the System Test select 1 from the DIAGNOSTIC TEST MENU, press Enter and
follow the directions on the screen. Move the highlight bar to the subtest you want to execute and
press Enter.
Subtest 01 ROM Checksum
This subtest executes a checksum test of the BIOS ROM on the System Board.
Subtest 04 Fan On/Off
This subtest checks CPU fan operation using the on/off command. The following
message will appear when this subtest is executed. Make sure the fan does not
rotate and press Enter.
*** Test Fan Revolution 0000RPM Start
The following message will appear. Make sure the fan rotates at low speed and
press Enter.
*** Test Fan Revolution Low speed start
The following message will appear. Make sure the fan rotates at high speed and
press Enter.
*** Test Fan Revolution High speed start
Subtest 05 Gerserville
If the CPU supports Gerserville (SpeedStep), this Subtest checks that the CPU
operating clock speed can be changed.
Subtest 06 Quick charge
This subtest checks the status for the quick charge.
Subtest 07 DMI read
Reads the factory setting for the serial and DMI numbers.
Model Name :
XXXXXX
Version Number :
XXXXXX-XXXXX
Serial Number :
XXXXXXXXXX
Model Number :
XXXXXX-XXXXX
PCN/BND Number :
XXXXXXXXXXXXXXXXXXXX
UUID Number :
XXXXXXXXXXXXXXXXXXXXXXXXX