1.12.2 Battery Charging Control
Battery charging is controlled by a power supply microprocessor. The microprocessor controls
whether the charge is on or off and detects a full charge when the AC adaptor and battery are
attached to the computer. The system charges the battery using quick charge.
Quick Battery Charge
When the AC adaptor is attached, there are two types of quick charge: quick charge 1 when the
system is powered off and quick charge 2 when the system is powered on.
Table 1-11 Time required for quick charges
Status Charging time
9 cell About 2.8 hours
Quick charge 1
(Power off)
6 cell About 2.5 hours
About 7 hours (When Windows is idling.)
9 cell
About 15 hours (When DVD is being played.)
About 5 hours (When Windows is idling.)
Quick charge 2
(Power on)
6 cell
About 11 hours (When DVD is being played.)
NOTE: The time required for quick charge 2 is affected by the amount of power the system
is consuming. Use of the fluorescent lamp and frequent disk access diverts power and
lengthens the charge time.
If any of the following occurs, the battery quick charge process stops.
1. The battery becomes fully charged.
2. The AC adaptor or battery is removed.
3. The battery or output voltage is abnormal.
q Detection of full charge
A full charge is detected only when the battery is charging at quick charge. A full charge is detected
under any of the following conditions:
1. The current in the battery charging circuit drops under the predetermined limit.
2. The charging time exceeds the fixed limit.