4.25 Fluorescent Lamp 4 Replacement Procedure
TECRA M1 Maintenance Manual (960-436) 4-109
9. Install the protection cover S (A), protection cover G (B), aluminum tape (C) and fixing
tape for lead wire (D). Use new parts.
• Stick the protection covers in the order of (B), (A) to the standard line for fitting pin.
• Stick the aluminum tape (C) following the sticking standards.
Long sides: Stick to the mark-off line of the lamp cover on the back of bezel.
Short sides: Stick to the edge of lamp cover.
• Stick the fixing wire for lead wire following the sticking standards.
Long sides: Stick to the outline of the LCD module.
Short sides: Stick so that the wire covers the screws.
Latch
(A) Protection cover S
(D) Fixing tape
for lead wire
(B) Protection cover G
(C) Aluminum tape
Figure 4-70 Replacing Sharp fluorescent lamp (SXGA+) (9)